Review of Scientific Instruments

Modified Fabry-Perot interferometer for displacement measurement in ultra large measuring range

Chung-Ping Chang, Pi-Cheng Tung, Lih-Horng Shyu, Yung-Cheng Wang, and Eberhard Manske
Laser interferometers have demonstrated outstanding measuring performances for high precision positioning or dimensional measurements in the precision industry, especially in the length measurement. Due to the non-common-optical-path structure, appreciable measurement errors can be easily induced un ... [Rev. Sci. Instrum. 84, 053105 (2013)] published Tue May 14, 2013.

Improving the accuracy of optical rotation measurement based on optical null methods by curve-fitting

Zhenhao Yang and Hongzhi Jia
An optical rotation measuring system using optical null methods is set up. The system is based on a step-motor rotating stage structure and a modulated laser, which both are controlled by digital signal processor. By introducing a curve-fitting method, the optical rotation angle is obtained from the ... [Rev. Sci. Instrum. 84, 053104 (2013)] published Mon May 13, 2013.

Generation of first hard X-ray pulse at Tsinghua Thomson Scattering X-ray Source

Yingchao Du

(杜应超)

, Lixin Yan

(颜立新)

, Jianfei Hua

(华剑飞)

, Qiang Du

(杜强)

, Zhen Zhang

(张振)

et al.
Tsinghua Thomson Scattering X-ray Source (TTX) is the first-of-its-kind dedicated hard X-ray source in China based on the Thomson scattering between a terawatt ultrashort laser and relativistic electron beams. In this paper, we report the experimental generation and characterization of the first har ... [Rev. Sci. Instrum. 84, 053301 (2013)] published Wed May 8, 2013.

Note: High-performance HeNe laser feedback interferometer with birefringence feedback cavity scanned by piezoelectric transducer

Yun Wu, Yidong Tan, Zhaoli Zeng, and Shulian Zhang
We demonstrate a high-performance HeNe laser feedback interferometer (HLFI) based on a birefringence feedback cavity scanned by a piezoelectric transducer (PZT). The PZT scanning technique leads to a significant improvement in the HLFI's anti-jamming capability. The null drift under general laborato ... [Rev. Sci. Instrum. 84, 056103 (2013)] published Mon May 6, 2013.

An innovative method for coordinate measuring machine one-dimensional self-calibration with simplified experimental process

Cheng Fang and David Lee Butler
In this paper, an innovative method for CMM (Coordinate Measuring Machine) self-calibration is proposed. In contrast to conventional CMM calibration that relies heavily on a high precision reference standard such as a laser interferometer, the proposed calibration method is based on a low-cost artef ... [Rev. Sci. Instrum. 84, 055103 (2013)] published Fri May 3, 2013.

Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic

E. L. Foley and F. M. Levinton
The motional Stark effect with laser-induced fluorescence diagnostic (MSE-LIF) has been installed and tested on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Lab. The MSE-LIF diagnostic will be capable of measuring radially resolved profiles of magnetic field magnitu ... [Rev. Sci. Instrum. 84, 043110 (2013)] published Mon Apr 29, 2013.

Revision of laser-induced damage threshold evaluation from damage probability data

Gintare BataviCiute, Povilas Grigas, Linas Smalakys, and Andrius Melninkaitis
In this study, the applicability of commonly used Damage Frequency Method (DFM) is addressed in the context of Laser-Induced Damage Threshold (LIDT) testing with pulsed lasers. A simplified computer model representing the statistical interaction between laser irradiation and randomly distributed dam ... [Rev. Sci. Instrum. 84, 045108 (2013)] published Fri Apr 26, 2013.

Note: Generation of Raman laser beams based on a sideband injection-locking technique using a fiber electro-optical modulator

H. B. Xue, Y. Y. Feng, X. J. Wang, S. Chen, and Z. Y. Zhou
Two phase-coherent Raman laser beams with a frequency offset of 6.835 GHz were generated by sideband injection-locking technique. A master diode laser was phase-modulated at 6.835 GHz by a fiber electro-optic modulator. A slave diode was injection-locked to the 1 sideband of the phase-modulated beam ... [Rev. Sci. Instrum. 84, 046104 (2013)] published Tue Apr 23, 2013.

Simultaneous measurement of thermal conductivity and thermal contact resistance of individual carbon fibers using Raman spectroscopy

Jinhui Liu, Haidong Wang, Weigang Ma, Xing Zhang, and Yan Song
In this paper, a new method employing Raman spectroscopy to determine thermal conductivity (TC) and thermal contact resistance (TCR) of an individual fiber was developed. Laser absorption is accounted for, but there is no need to be determined in this method. The local temperatures along the fiber l ... [Rev. Sci. Instrum. 84, 044901 (2013)] published Mon Apr 22, 2013.

The magnetic recoil spectrometer for measurements of the absolute neutron spectrum at OMEGA and the NIF

D. T. Casey, J. A. Frenje, M. Gatu Johnson, F. H. Seguin, C. K. Li et al.
The neutron spectrum produced by deuterium-tritium (DT) inertial confinement fusion implosions contains a wealth of information about implosion performance including the DT yield, ion-temperature, and areal-density. The Magnetic Recoil Spectrometer (MRS) has been used at both the OMEGA laser facilit ... [Rev. Sci. Instrum. 84, 043506 (2013)] published Thu Apr 18, 2013.

Syndicate content